Temperature: | Ordinary Temperature |
---|---|
Certification: | RoHS, CE, ISO9001 |
Media: | Gas |
Standard: | Standard |
Connection Mode: | Thread |
Power: | Magnetic |
Samples: |
---|
Customization: |
---|
Suppliers with verified business licenses
Overpressure automatic shutdown
When the pressure regulator at the front end of the gas pipeline works abnormally or the pipeline pressure is too high due to the pipeline pressure test conducted by the gas company and exceeds the overpressure setting value of the pipeline gas self-closing valve, the valve will automatically close due to the overpressure to prevent the overpressure caused by the pipeline pressure. Excessively high and gas leakage occurs.
Underpressure automatic shutdown
When the pressure regulator at the front end of the gas pipeline is abnormal, during the peak period of gas consumption, the gas pipeline is frozen and blocked, gas shortage in winter, gas shutdown, replacement, decompression and other operations cause the pipeline pressure to drop and fall below the set value, The valve will automatically close under pressure to prevent gas leakage accidents that may occur when the air pressure is restored.
Overflow automatic shutdown
When the gas source switch and the front-end pressure regulator of the gas pipeline are abnormal, or the rubber hose falls off, ages, ruptures, the aluminum-plastic pipe and metal hose are perforated by electric corrosion, cracks appear in stress changes, the connection is loose, and the gas stove is abnormal, etc., When the gas flow in the pipeline overflows for a long time and exceeds the set value of the overcurrent flow of the valve, the valve will automatically close due to overcurrent, interrupting the gas supply, and preventing possible safety accidents caused by excessive gas outflow.
Items | Data |
Model No. | GDF-2 |
Customized | OEM,ODM |
Temperature | High Temperature, Low Temperature |
Storage temperature. | -20°C-60°C |
Operating temperature | 20°C-60°C |
Humidity. | 5%-90% |
Port Size: | customize |
Operating pressure | 0-2kPa |
Overpressure self-closing pressure | 8+2kPa |
Underpressure self-closing pressure | 0.8+0.2kPa |
Overflow self-closing flow | 1.4/2.0/4.0m3/h |
Rated Flow. | 0.7/1.0/2.0m3/h |
Material | ADC12,NBR |
Closing time. | ≤3s |
Power. | Electric |
Working medium | Natural gas,Coal gas |
Leakage. | CJ/T 447-2014 |
Certification: | Reach, Rohs,ATEX |